硅酸根分析儀儀器校準

1.按電源開關,開機(ji)后(hou),進(jin)入測量狀態,液晶顯(xian)示(shi)如下(xia):左上(shang)角為當(dang)前(qian)時(shi)間,顯(xian)示(shi)如下(xia)主(zhu)菜單: 12: 0019.6ug/L 命(ming)令行(xing)(xing):排(pai)污本儀(yi)器(qi)命(ming)令行(xing)(xing)有(you)排(pai)污、打印(yin)數(shu)據、自動(dong)校準(zhun)、建立自動(dong)校準(zhun)標準(zhun)、儀(yi)器(qi)時(shi)間、 校準(zhun)記錄(lu)、運行(xing)(xing)記錄(lu)、數(shu)據記錄(lu)、修改密(mi)碼(ma)、計時(shi)、存(cun)儲(chu)數(shu)據等功能(neng)。用增加鍵或減少鍵選(xuan)(xuan)擇需要的功能(neng),按下(xia)確認鍵后(hou)進(jin)入所選(xuan)(xuan)的功能(neng),按下(xia)退出(chu)鍵后(hou)退出(chu)所選(xuan)(xuan)的功能(neng)。

2.在(zai)進樣杯中加滿(man)脫鹽水。待溢流(liu)結(jie)束后用增加鍵(jian)進入排(pai)污(wu)(wu)菜(cai)單(dan)后,按下確(que)認鍵(jian),儀器內排(pai)污(wu)(wu)閥可自動打(da)開,儀器內比色池(chi)中脫鹽水立即(ji)排(pai)放,此(ci)時屏(ping)幕(mu)顯(xian)(xian)(xian)示(shi)如(ru)(ru)下: 12: 0019.6ug/L 正(zheng)在(zai)排(pai)污(wu)(wu),請稍候! 014 屏(ping)幕(mu)右上角(jiao)顯(xian)(xian)(xian)示(shi)的(de)數字值為離儀器排(pai)污(wu)(wu)結(jie)束時還需等待的(de)時間,如(ru)(ru)果提前結(jie)束排(pai)污(wu)(wu),按退出鍵(jian)即(ji)可。當(dang)儀器自動結(jie)束排(pai)污(wu)(wu)時,此(ci)時屏(ping)幕(mu)顯(xian)(xian)(xian)示(shi)如(ru)(ru)下: 12: 00 19.6ug/L命令行:排(pai)污(wu)(wu)

3.用(yong)增加(jia)鍵(jian)(jian)(jian)或減少(shao)鍵(jian)(jian)(jian)選擇化學(xue)校(xiao)準(zhun)的(de)功能,按(an)(an)(an)下(xia)(xia)(xia)確(que)(que)(que)認(ren)鍵(jian)(jian)(jian)后(hou)(hou),此(ci)(ci)時(shi)屏幕(mu)顯(xian)示(shi)(shi)如下(xia)(xia)(xia): 12: 00 19.6ugL命令行:化學(xue)校(xiao)準(zhun)12: 00 19.6ugL請(qing)輸入密(mi)碼: 0000用(yong)增加(jia)鍵(jian)(jian)(jian)或減少(shao)鍵(jian)(jian)(jian)輸入儀(yi)器(qi)(qi)設定(ding)的(de)密(mi)碼位(wei)(儀(yi)器(qi)(qi)出廠 設定(ding)的(de)原始(shi)密(mi)碼為000)輸入正(zheng)確(que)(que)(que)后(hou)(hou), ,按(an)(an)(an)下(xia)(xia)(xia)確(que)(que)(que)認(ren)鍵(jian)(jian)(jian)進行移位(wei),待最(zui)后(hou)(hou)一位(wei)密(mi)碼輸入完畢(bi)后(hou)(hou),按(an)(an)(an)下(xia)(xia)(xia)確(que)(que)(que)認(ren)鍵(jian)(jian)(jian),此(ci)(ci)時(shi)屏幕(mu)顯(xian)示(shi)(shi)如下(xia)(xia)(xia):請(qing)首先將(jiang)(jiang)比(bi)(bi)色(se)池(chi)沖洗(xi)干(gan)凈(jing)(jing),然后(hou)(hou)按(an)(an)(an)確(que)(que)(que)認(ren)鍵(jian)(jian)(jian)繼(ji)續(xu),否則按(an)(an)(an)退(tui)出鍵(jian)(jian)(jian)取消化學(xue)校(xiao)準(zhun)!當比(bi)(bi)色(se)池(chi)沖洗(xi)干(gan)凈(jing)(jing)時(shi)按(an)(an)(an)下(xia)(xia)(xia)確(que)(que)(que)定(ding)鍵(jian)(jian)(jian), 此(ci)(ci)時(shi)屏幕(mu)顯(xian)示(shi)(shi)如下(xia)(xia)(xia):標液(ye)一濃度: 00.0ug/L 1950.2 mv 1172.8mv待數值穩定(ding)后(hou)(hou)按(an)(an)(an)確(que)(que)(que)定(ding)鍵(jian)(jian)(jian)繼(ji)續(xu)!加(jia)入試劑后(hou)(hou),按(an)(an)(an)下(xia)(xia)(xia)確(que)(que)(que)定(ding)鍵(jian)(jian)(jian),此(ci)(ci)時(shi)屏幕(mu)顯(xian)示(shi)(shi)如下(xia)(xia)(xia):第(di)=點校(xiao)準(zhun),按(an)(an)(an)上鍵(jian)(jian)(jian)排(pai)污,將(jiang)(jiang)比(bi)(bi)色(se)池(chi)沖洗(xi)干(gan)凈(jing)(jing),然后(hou)(hou)按(an)(an)(an)確(que)(que)(que)認(ren)鍵(jian)(jian)(jian)繼(ji)續(xu)!按(an)(an)(an)上鍵(jian)(jian)(jian)排(pai)污,將(jiang)(jiang)比(bi)(bi)色(se)池(chi)中的(de)標液(ye)一排(pai)出, 然后(hou)(hou)在進樣杯杯中加(jia)滿脫鹽水,按(an)(an)(an)上鍵(jian)(jian)(jian)排(pai)污,重復該操作(zuo)3-4次,將(jiang)(jiang)比(bi)(bi)色(se)池(chi)沖洗(xi)干(gan)凈(jing)(jing)后(hou)(hou),按(an)(an)(an)屏幕(mu)上提示(shi)(shi)重復以上操作(zuo),用(yong)標液(ye)二對儀(yi)器(qi)(qi)進行校(xiao)準(zhun)。


021-51879017
歡迎您的咨詢
我們將竭盡全力為您用心服務
在線客服
關注微信
版權所有 © 2024 上海羽通儀器儀表廠  
技術支持:    sitemap.xml